While property owners often confuse the two, a Perc Test and a Geotechnical Report serve entirely different purposes and cannot be used interchangeably for structural work.
### Perc Test (Percolation Test)
- Primary Purpose: Used solely for septic system design.
- Key Data: It measures the soil’s absorption rate in minutes per inch to determine the size of a leach field.
- Structural Relevance: It provides no data on whether soil can support a building. Building departments will not accept a perc test for foundation permits.
- Typical Cost: $100 – $300 per test hole.
### Geotechnical Report
- Primary Purpose: Evaluates soil bearing capacity for structural foundation design and repair.
- Key Data: Provides comprehensive technical details including soil type classification, density, groundwater depth, shear strength, and shrink/swell potential.
- Structural Relevance: Essential for calculating foundation dimensions and determining the depth and spacing of helical piers.
- Typical Cost: $800 – $3,500 depending on the project scope and site access.
In the Denver metro area, geotechnical reports must be prepared by a licensed geotechnical engineer and follow ASTM standards to ensure the long-term stability of the structure.
Related FAQs
-
Do Sticking Doors and Windows in a New Home Always Indicate Significant Foundation Settlement?
Read More »: Do Sticking Doors and Windows in a New Home Always Indicate Significant Foundation Settlement?No, sticking doors and windows do not always indicate a significant problem. In a newly built home, some sticking is considered a normal part of the initial settling process as the structure acclimates to its environment, particularly during the first…
-
How do Engineers Calculate the Ultimate Geotechnical Capacity of a Helical Pile?
Read More »: How do Engineers Calculate the Ultimate Geotechnical Capacity of a Helical Pile?To calculate the ultimate geotechnical capacity of a helical pile, our engineers utilize three complementary approaches that combine soil mechanics theory with real-world field verification: We always apply a safety factor—typically between 2.0 and 3.0—to these ultimate capacity results to…
-
Does the Water Table Level Affect the Soil Bearing Capacity for Helical Piers?
Read More »: Does the Water Table Level Affect the Soil Bearing Capacity for Helical Piers?Yes, the water table level significantly influences soil bearing capacity for helical piers. Groundwater conditions can alter the engineering properties of the soil, which our team must account for during both the design and installation phases. Saturated soils experience reduced…
-
What is the Relationship between Installation Torque and Soil Bearing Capacity?
Read More »: What is the Relationship between Installation Torque and Soil Bearing Capacity?The relationship between installation torque and soil bearing capacity is governed by an empirical correlation that allows us to estimate the ultimate load-bearing strength of a pier based on the rotational force required to install it. This is expressed through…
-
How is the Soil Bearing Capacity Determined for Helical Pier Installation?
Read More »: How is the Soil Bearing Capacity Determined for Helical Pier Installation?To determine soil bearing capacity for helical pier installation, we use a multi-layered approach that combines theoretical engineering, real-time field measurements, and specialized testing. Our process ensures that structural loads are transferred past weak surface soils—such as the expansive clay…